PHYSICAL AND MECHANICAL SPECIFICATIONS OF RAIN GUTTERS

Test Test Method Requirement
Impact Resistance TS EN 607 EK B When looked without lenses, no breaks and cracks should be observed
Tensile Strength EN ISO 6259-2 Minimum 42 Mpa
Lengthwise Elongation at Rupture EN ISO 6259-2 Minimum %100
Pull Impact Resistance EN ISO 8256 Minimum 500 kj / m
Thermal Stability EN ISO 2505 Maximum 3% - No deformation or surface defect
Vicat Softening Temperature EN ISO 2507-1 Should not soften up to minimum 75 °C.

PHYSICAL AND MECHANICAL SPECIFICATIONS OF RAIN GUTTER FITTINGS

Test Test Method Requirement Test Conditions
Heating Effect EN ISO 580 Should not present crack at wall thicknesses in the mould stain point. kept under 150 °C for 15 min.
Thermal Stability EK C No deformation 3 samples at 65 + 2 °C for 30 + 2 min.
Vicat Softening Temperature EN ISO 2507-1 Should not soften up to minimum 75 °C.  

Fittings Appearance:  When looked without lens, internal and external surfaces must be smooth and clean, there should not be surface defects such as bubbles and dints. 

Shape and Dimensions of Fittings:  Fittings must be complied with shape and profile dimensions of rain gutters. 

SYSTEM COMPLIANCE OF RAIN GUTTERS

Test Test Method Requirement Test Conditions
Artificial Ageing Xenon Test  ISO 4892-2 2.6 Gj/m2, Water Cycle, at 45+3ºC, at %50+5 relative humidity, 3' / 17'
Color Fastness EN 20105-A02 Color Change
TS 423-2 EN 
Should not exceed number 3 in grey scale given in 20105-A02
3 samples at 65 + 2 °C for 30 + 2 min.
Shrinkage after Ageing 
Impact Resistance
EN ISO 8256:Metot A Minimum 50% of the value before artificial ageing At 23+2ºC
Water Tightness Test EK D No deformation Water is circulated at 50+2ºC for 15 min, at 15+2ºC for 10 min. Water flow rate must be 18 L/min.